CRISP
This page collects information that will be useful for the implementation of the IBEX control system on CRISP.
Background & Timeline
CRISP is a reflectometer instrument at ISIS, on TS1. The CRISP web page describes the background to the instrument.
Control System
CRISP will migrate from the SECI control system to the IBEX control system in MMMMMMMM YYYY.
CRISP Equipment
The equipment listed below is used on CRISP. Please add new information (e.g. new items of equipment, new notes, information about drivers, etc. to this table).
Manufacturer |
Model |
Type |
Connection |
Driver |
Notes |
---|---|---|---|---|---|
ISIS |
DAE 2 |
Detector Electronics |
Ethernet |
||
ISIS |
Mk3 |
Chopper |
N/A |
||
GALIL |
Motion Controller |
Ethernet |
|||
??? |
4-blade jaws |
||||
ISIS |
??? |
ISIS Vacuum System |
|||
Pfeiffer |
TPG300 |
Vacuum Gauge |
RS-232 |
EPICS |
|
Eurotherm |
Temperature Controller |
All models at ISIS |
RS-232 |
||
Oxford Instruments |
Orange Cryostat |
Cryogenic System |
|||
Oxford Instruments |
Blue Cryostat |
Cryogenic System |
|||
Closed Cycle Refrigerator |
|||||
Julabo |
FP-50 |
Water Bath |
RS-232 |
||
Julabo |
FP-52 |
Water Bath |
RS-232 |
||
~Grant Instruments~ |
??? |
~Water Bath~ |
RS-232 |
||
~Haake~ |
~N6~ |
~Water Bath~ |
RS-232 |
||
Keithley |
2000 |
Multimeter |
RS-232 |
||
Keithley |
2602 |
Source Meter |
RS-232 |
||
Hirst |
GM05 |
Gaussmeter |
??? |
||
Knauer |
K-6 |
Electric Valve Drive |
??? |
||
Knauer |
1050 |
HPLC pump |
??? |
||
Hitachi |
L-7100 |
HPLC pump |
??? |
||
Nima Trough |
??? |
Trough |
??? |
||
Thurlby |
EX355P |
PSU |
??? |
||
Watson Marlow |
323 |
Syringe Pump |
??? |
||
WPI |
Aladdin-1000 |
Syringe Pump |
??? |
||
WPI |
SP2xx |
Syringe Pump |
??? |
||
??? |
??? |
He3 Monitor |
??? |
Note: DAE
See multi-detector and single-detector below.
Note: Choppers
CRISP has a Mk3 chopper.
Note: Jaws
Provide information about CRISP jaws.
Note: Vacuum System
Note: Eurotherm
Eurotherms are used to control temperature Orange Cryostat, CCR and Furnace devices.
Note: Oxford Instruments
Note: Closed Cycle Refrigerators
Note: Water Baths
CRISP uses two types of water bath
Julabo (which model(s)?)
Grant Water Bath
Update (25-06-2019): Grant water baths are no longer used. No longer any need to support them. See #4457
Haake N6 Water Bath. Haake has now been taken over by ThermoFisher. N6 model may be obsolete. Check existing SECI VI for logic and manual.
Update (25-06-2019): Haake water baths are no longer used. No longer any need to support them. See #4456
Note: Keithley
Note: Hirst
Note: Hitachi
Hitachi L-7100 HPLC pump. Can’t find L-7100 on Hitachi web-site (may be obsolete). Check existing SECI VI for logic and manual.
Note: Knauer
Knauer K-6 Electric Valve Drive. Knauer web site
K-6 model appears to have been superseded. Check existing SECI VI for logic and manual.
Note: Knauer HPLC
Knauer HPLC 1050 Knauer HPLC 1050 is discontinued.. Check existing SECI VI for logic and manual.
Note: Nima Trough
Nima Trough: SECI used a manufacturer supplied VI. We may need to do the same in IBEX (via lvDCOM).
Note: NIMA Technologies Ltd now seems to be part of Biolin Scientific.
The NIMA trough is used regularly on SURF. The manufacturer supplied VI is used to view graphs showing information about thin films.
The manufacturer has made additional software available for download. A copy of this software is located in
\\isis\shares\ISIS_Experiment_Controls\NIMA Trough\Nima_TR8.1.zip
.
Note: Thurlby
Note: Syringe Pumps
WPI SP2xx Syringe Pump - check specific model.
Note: He3 Monitor
He3 Monitor is an obsolete piece of equipment. It is no longer used. No need to support it.
CRISP SECI Configs
Document information about CRISP SECI configs here.
Configuration Name |
Sub-Configurations |
Last Accessed |
Required |
---|---|---|---|
CRISP_place_holder1.conf |
- |
dd/mm/yyyy |
- |
CRISP_place_holder2.conf |
- |
dd/mm/yyyy |
- |
CRISP Genie Scripts
Similarly, Document information about CRISP SECI Genie scripts here.
CRISP Notes
CRISP has the following specialist panels:
CRISP setup dialogue
CRISP User Front Panel
CRISP analyser stage
INTER High Voltage
SURF Galil analogue output
SURF Galil DIO
CRISP has the following devices under motion control:
goniometer
jaws & height
jaws
multi-detector
single-detector
supermirror
transmission monitor
XYZ stage
CRISP has the following item:
LSS Scan calculator (is this a script?)